The questions our engineers answer most often — how the standards behave, which part fits which job, what to check when something will not power up, and how custom orders work.

PoE basics

What is Power over Ethernet?

PoE lets a single twisted-pair cable carry both Ethernet data and DC power to a device, removing the need for a separate power outlet at the far end. Power sourcing equipment (a PoE switch or injector) negotiates with the powered device before applying voltage, so power is only ever delivered to hardware designed to receive it.

What is the difference between 802.3af, 802.3at and 802.3bt?

They are the three ratified generations of standardized PoE. 802.3af (Type 1) sources up to 15.4 W per port with 12.95 W guaranteed at the device. 802.3at (Type 2, PoE+) raises that to 30 W and 25.5 W. 802.3bt adds Type 3 at 60 W / 51 W and Type 4 at 90 W / 71.3 W, using all four pairs instead of two. Each generation is backward compatible with the ones before it, but not forward compatible.

Will PoE damage a device that does not support it?

No, provided the source is standards-compliant. Before applying operating voltage, the PSE probes for a characteristic 25 kΩ signature resistance that every compliant powered device presents. Without that signature no power is applied, which is why an ordinary laptop or printer is safe on a PoE port. Passive PoE equipment skips this check entirely and can damage hardware — that is the case to watch for.

How far can PoE reach?

The Ethernet channel limit of 100 m applies, made up of 90 m of horizontal cable plus patch cords. The limit comes from signal attenuation and timing, not from power. To go further you either add a PoE extender, which regenerates the signal and resets the budget roughly every 100 m, or move to fiber and regenerate power locally.

What is the difference between active and passive PoE?

Active PoE follows the IEEE 802.3 standards: detection, classification, then power. Passive PoE simply applies a fixed DC voltage to fixed pins the moment it is switched on, with no negotiation. Passive equipment works only in a closed system where both ends are known and matched. If a datasheet does not name an IEEE standard, assume it is passive.

Choosing the right product

Splitter, injector, extender or switch — which do I need?

An injector adds power to a run coming from a non-PoE switch. A PoE switch does the same thing but for every port at once, and is more economical past roughly six to eight devices. A splitter does the reverse: it separates power back out for a device that has no PoE support, delivering DC at 5 V, 12 V or 24 V. An extender regenerates data and power to push a link past 100 m.

How do I know which output voltage to order on a splitter?

Match the device you are powering, not the network. Check its power input label or datasheet for voltage, current and connector, and order the splitter that matches all three including polarity. Ordering by voltage alone is the most common mistake — a correct 12 V output on the wrong barrel size or reversed polarity is still unusable.

Do I need a gigabit model?

A 10/100 splitter or extender is genuinely adequate for a single 1080p camera stream and costs less. It becomes a bottleneck for a 4K camera, a branch feeding several devices, or anything shared with an access point, and the failure looks like intermittent video artefacts rather than an obvious outage. If the link carries anything beyond one modest camera, specify gigabit.

How do I work out the power budget for a switch?

Add up the PSE-side class reservation for every port you intend to populate — not the measured draw — and compare that against the switch total PoE budget, which is almost always far lower than the per-port maximum multiplied by the port count. Leave at least 20 % headroom for growth and for devices that draw more in cold weather.

Can I use these products outdoors?

Only the models rated for it. Check the operating temperature range and any ingress rating against the real environment — an enclosure in direct sun runs well above ambient and an unheated cabinet in winter goes well below freezing. Commercial-grade equipment rated 0 °C to 40 °C is not suitable for a roadside cabinet or a pole mount. We list waterproof-rated extenders and splitters for these cases.

Installation and troubleshooting

I measured 0 V on the PoE port. Is it faulty?

Almost certainly not. A compliant PSE presents no operating voltage into an open port — it waits until it detects a valid powered device. Reading 0 V on an unloaded port is correct behaviour, and misreading it is probably the most common false diagnosis in PoE troubleshooting. Use a PoE loader or tester that presents a real PD signature to test the port properly.

My device powers on but some features do not work. Why?

That is the classic signature of insufficient power. Rather than failing outright, modern devices boot and then disable capabilities to fit their allocation — a camera may run but leave the heater and zoom motor dead, and an access point may shut down a radio or halve its transmit chains. Check the negotiated class on the switch and compare it against what the device requires.

What cable should I use?

Cat5e is the practical minimum for gigabit and standard PoE. Cat6 or Cat6a with 23 AWG conductors is the right specification for Type 3 and Type 4 power: lower resistance per metre, better heat dissipation and headroom for higher speeds later. Avoid thin 26 AWG or 28 AWG patch cords on high-power runs — a pair of long ones can consume a large share of the channel resistance budget.

Why do cameras fail only in winter, or only at night?

Both are power problems in disguise. At night the IR illuminator switches on; in winter the heater does too, and either can double a camera draw. If the design was budgeted against the daytime summer figure, or the camera sits at the end of a long run where delivered voltage is already low, that extra load is what pushes it into a reset loop.

How many extenders can I chain together?

Most installations cascade three or four for a practical reach of 400 m to 500 m. Signal quality is not the constraint because each unit regenerates the link — power is. Allow roughly 6 W per hop for the extender electronics plus cable loss, work backwards from what the end device needs, and feed long chains from a higher-class source port.

Do I need surge protection?

For any run that goes outdoors, up a mast, or between separate buildings, yes. Ethernet transformer isolation handles modest common-mode differences but is not lightning protection, and PoE partially defeats it by creating a DC path through the magnetics. Fit a PoE-rated protector at each end of external runs, bond it to local earth, and use fiber between structures with independent earthing systems.

Ordering and customisation

What is the minimum order quantity?

MOQ is listed on each product page. Send an enquiry with the item, your target volume and the destination and we will come back with pricing.

Do you support OEM and ODM?

Yes. We design PoE PD front-ends and DC-DC stages in-house and manufacture on our own SMT and assembly lines, so output voltage and connector, cable length, enclosure and labelling, packaging and firmware behaviour are all customisable. We also take on full ODM development from a written specification.

How does a custom project run?

Three stages. You share the output voltage, connector, application and any certification requirements; we design the module and deliver samples for validation, typically within two to four weeks; once you approve the design it moves to mass production with full QC. The custom manufacturing page sets out what we need from you to quote.

Are your products certified?

Our products are built to CE, FCC and RoHS requirements. If your market or customer requires specific certification documents or additional approvals, raise it at the enquiry stage so we can confirm what applies to the exact model before you order.

How are units tested before shipment?

Every unit is functionally tested for voltage, load and protection before it leaves the line. Quality control runs in-house alongside production rather than being subcontracted.

I am not sure which part I need. Can you help?

Yes, and it is the fastest way to get this right. Tell us the device you need to power, its voltage and connector, the distance to the nearest switch and the environment it sits in. That is usually enough for us to specify the part, and it avoids the common failure of ordering on voltage alone.

Still stuck?

Send us the device, the distance and the environment. That is usually enough for us to specify the right part first time.